1.
Eur J Radiol ; 175: 111448, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38574510

RESUMO

PURPOSE: Aim of the recent study is to point out a method to optimize quality of CT scans in oncological patients with port systems. This study investigates the potential of photon counting computed tomography (PCCT) for reduction of beam hardening artifacts caused by port-implants in chest imaging by means of spectral reconstructions. METHOD: In this retrospective single-center study, 8 ROIs for 19 spectral reconstructions (polyenergetic imaging, monoenergetic reconstructions from 40 to 190 keV as well as iodine maps and virtual non contrast (VNC)) of 49 patients with pectoral port systems undergoing PCCT of the chest for staging of oncologic disease were measured. Mean values and standard deviation (SD) Hounsfield unit measurements of port-chamber associated hypo- and hyperdense artifacts, bilateral muscles and vessels has been carried out. Also, a structured assessment of artifacts and imaging findings was performed by two radiologists. RESULTS: A significant association of keV with iodine contrast as well as artifact intensity was noted (all p < 0.001). In qualitative assessment, utilization of 120 keV monoenergetic reconstructions could reduce severe and pronounced artifacts completely, as compared to lower keV reconstructions (p < 0.001). Regarding imaging findings, no significant difference between monoenergetic reconstructions was noted (all p > 0.05). In cases with very high iodine concentrations in the subclavian vein, image distortions were noted at 40 keV images (p < 0.01). CONCLUSIONS: The present study demonstrates that PCCT derived spectral reconstructions can be used in oncological imaging of the thorax to reduce port-derived beam-hardening artefacts. When evaluating image data sets within a staging, it can be particularly helpful to consider the 120 keV VMIs, in which the artefacts are comparatively low.

2.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535045

RESUMO

OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.

3.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535047

RESUMO

BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds. OBJECTIVE: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels. METHODS: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany). The attenuation of abdominal arteries on pv phases was measured for different virtual keV levels in a monoenergetic+ application profile and for polychromatic (pc) arterial images. Two independent readers assessed subjective image quality, including vascular contrast in pv scans at different energy levels. Additionally, signal- and contrast-to-noise ratios (SNR and CNR) were measured. RESULTS: Our results showed increasing arterial attenuation levels with decreasing energy levels in virtual monoenergetic imaging on pv scans with the highest attenuation at 40 keV, significantly higher than in the pc arterial phase (439 ± 97 HU vs. 360 ± 97, p < 0.001). Noise, SNR, and CNR were worse at this energy level (p < 0.001). Pv VMI showed less noise at energy levels above 70 keV (all p < 0.001). Subjective image quality was rated best at 70 keV, vascular contrast was best at 40 keV. CONCLUSIONS: Our research suggests that virtual monoenergetic images at 40 keV in Mono+ mode derived from a PCD-CT can be a feasible alternative to a true arterial phase for assessment of vessels with worse CNR and SNR.

4.
Dentomaxillofac Radiol ; 53(2): 103-108, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38330501

RESUMO

PURPOSE: This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy. METHODS: This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques. RESULTS: Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv ± 0.009 vs. 0.14 mSv ± 0.011; P < .001). CONCLUSION: In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT.


Assuntos
Seios Paranasais , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Seios Paranasais/diagnóstico por imagem , Imagens de Fantasmas
5.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
6.
Front Cardiovasc Med ; 10: 1223035, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37965085

RESUMO

Introduction: Pericoronary adipose tissue (PCAT) stands in complex bidirectional interaction with the surrounding arteries and is known to be connected to many cardiovascular diseases involving vascular inflammation. PCAT texture may be influenced by other cardiovascular risk factors such as hypercholesterolemia. The recently established photon-counting CT could improve texture analysis and help detect those changes by offering higher spatial resolution and signal-to-noise ratio. Methods: In this retrospective, single-center, IRB-approved study, PCAT of the left and right coronary artery was manually segmented and radiomic features were extracted using pyradiomics. The study population consisted of a test collective and a validation collective. The collectives were each divided into two groups defined by the presence or absence of hypercholesterolemia, taken from self-reported conditions and confirmed by medical records. Mean and standard deviation were calculated with Pearson correlation coefficient for correlation of features and visualized as boxplots and heatmaps using R statistics. Random forest feature selection was performed to identify differentiating features between the two groups. 66 patients were enrolled in this study (34 female, mean age 58 years). Results: Two radiomics features allowing differentiation between PCAT texture of the groups were identified (p-values between 0.013 and 0.24) and validated. Patients with hypercholesterolemia presented with a greater concentration of high-density values as indicated through analysis of specific texture features as "gldm_HighGrayLevelEmphasis" (23.95 vs. 22.99) and "glrlm_HighGrayLevelRunEmphasis" (24.21 vs. 23.31). Discussion: Texture analysis of PCAT allowed differentiation between patients with and without hypercholesterolemia offering a potential imaging biomarker for this specific cardiovascular risk factor.

7.
Sci Rep ; 13(1): 12036, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491452

RESUMO

Pectus excavatum (PE) is a congenital malformation with a funnel-shaped depression of the sternum that can lead to cardiac symptoms. However, there are patients with thoracic constriction (defined as elevated Haller-Index > 3.25 determined by cardiac magnetic resonance imaging (CMR)) without visible evidence of PE, leading to similar complaints. Between January 2004 till June 2020, patients who underwent CMR for further evaluation of the heart, due to cardiac symptoms were enrolled and compared to controls. Biventricular global strain analysis was assessed using feature tracking (CMR-FT). ECG and/or Holter recordings were performed to detect rhythm events. Cardiac symptoms were evaluated in detail using a questionnaire. Finally, 88 patients (male 35, female 53) with elevated Haller-Index (3.9 ± 0.8) were included and compared to CMR data from 25 individuals with confirmed PE and 25 healthy controls (HC). Mean age at time of CMR was 35 ± 16 years. The most common symptoms at presentation were palpitations (41%), followed by dyspnea (24%) and atypical chest pain (14%). Three patients (3%) had atrial fibrillation or atrial flutter. Concomitant phenomena were pericardial effusion in 39% and mitral valve prolapse (MVP) in 27% of the study cohort. While there were no differences in left ventricular function or volumes, right ventricular function (RVEF) was significantly lower in patients with internal PE compared to HC (RVEF (%) 50 ± 5 vs 59 ± 4, p < 0.01). Strain analysis revealed only discrete changes in RV strain, implying a purely mechanical problem in the absence of structural changes. RV dimensions were negatively correlated with the size of thoracic indices (r = 0.41), reflecting the extent of thoracic constriction. MVP was more prevalent in patients with greater thoracic indices (r = 0.24). The described cohort, referred to as internal PE because of the absence of external changes, showed similar CMR morphologic findings as patients with real PE (especially altered dimensions of the right heart and a lower RVEF). In addition, there was a high incidence of rhythm disturbances, such as extrasystoles or arrhythmias. In one-third of the study cohort additional abnormalities such as pericardial effusion or MVP were present, with MVP being found more frequently in patients with larger thoracic indices, suggesting a possible common pathogenesis.Trial registration: ISRCTN registry, ISRCTN15355937, retrospectively registered 03.06.2022, https://www.isrctn.com/ISRCTN15355937?q=15355937&filters=&sort=&offset=1&totalResults=1&page=1&pageSize=10 .


Assuntos
Tórax em Funil , Prolapso da Valva Mitral , Derrame Pericárdico , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Tórax em Funil/diagnóstico por imagem , Derrame Pericárdico/complicações , Constrição , Imageamento por Ressonância Magnética , Coração , Imagem Cinética por Ressonância Magnética/métodos
8.
Diagnostics (Basel) ; 13(12)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37371011

RESUMO

This article describes the technical principles and clinical applications of dual-energy computed tomography (DECT) in the context of cardiothoracic imaging with a focus on current developments and techniques. Since the introduction of DECT, different vendors developed distinct hard and software approaches for generating multi-energy datasets and multiple DECT applications that were developed and clinically investigated for different fields of interest. Benefits for various clinical settings, such as oncology, trauma and emergency radiology, as well as musculoskeletal and cardiovascular imaging, were recently reported in the literature. State-of-the-art applications, such as virtual monoenergetic imaging (VMI), material decomposition, perfused blood volume imaging, virtual non-contrast imaging (VNC), plaque removal, and virtual non-calcium (VNCa) imaging, can significantly improve cardiothoracic CT image workflows and have a high potential for improvement of diagnostic accuracy and patient safety.

9.
Eur Radiol ; 33(11): 7840-7848, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37338555

RESUMO

OBJECTIVES: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). METHODS: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. RESULTS: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. CONCLUSIONS: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. CLINICAL RELEVANCE: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. KEY POINTS: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Sucção , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Meios de Contraste
10.
Diagnostics (Basel) ; 13(10)2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37238274

RESUMO

BACKGROUND: Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose. In recent years, VMI has been improved with the use of a new algorithm called VMI+, able to obtain the best image contrast with the least possible image noise in low-keV reconstructions. PURPOSE: To evaluate the impact of VMI+ DECT reconstructions on quantitative and qualitative image quality in the evaluation of the lower extremity runoff. MATERIALS AND METHODS: We evaluated DECT angiography of lower extremities in patients suffering from diabetes who had undergone clinically indicated DECT examinations between January 2018 and January 2023. Images were reconstructed with standard linear blending (F_0.5) and low VMI+ series were generated from 40 to 100 keV, in an interval of 15 keV. Vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for objective analysis. Subjective analysis was performed using five-point scales to evaluate image quality, image noise, and diagnostic assessability of vessel contrast. RESULTS: Our final study cohort consisted of 77 patients (41 males). Attenuation values, CNR, and SNR were higher in 40-keV VMI+ reconstructions compared to the remaining VMI+ and standard F_0.5 series (HU: 1180.41 ± 45.09; SNR: 29.91 ± 0.99; CNR: 28.60 ± 1.03 vs. HU 251.32 ± 7.13; SNR: 13.22 ± 0.44; CNR: 10.57 ± 0.39 in standard F_0.5 series) (p < 0.0001). Subjective image rating was significantly higher in 55-keV VMI+ images compared to the other VMI+ and standard F_0.5 series in terms of image quality (mean score: 4.77), image noise (mean score: 4.39), and assessability of vessel contrast (mean value: 4.57) (p < 0.001). CONCLUSIONS: DECT 40-keV and 55-keV VMI+ showed the highest objective and subjective parameters of image quality, respectively. These specific energy levels for VMI+ reconstructions could be recommended in clinical practice, providing high-quality images with greater diagnostic suitability for the evaluation of lower extremity runoff, and potentially needing a lower amount of contrast medium, which is particularly advantageous for diabetic patients.

11.
Rofo ; 195(8): 691-698, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36863367

RESUMO

BACKGROUND: Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today's workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms "Photon-Counting CT", "Photon-Counting detector", "spectral CT", "Computed Tomography" as well as on the authors' experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. KEY POINTS: · Photon-counting computed tomography (PCCT) has been implemented in the clinical routine. · Compared to energy-integrating detector CT, PCCT allows the reduction of electronic image noise. · PCCT provides increased spatial resolution and a higher contrast-to-noise ratio. · The novel detector technology allows the quantification of spectral information. CITATION FORMAT: · Stein T, Rau A, Russe MF et al. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience. Fortschr Röntgenstr 2023; 195: 691 - 698.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
12.
Diagnostics (Basel) ; 13(5)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36900082

RESUMO

PURPOSE: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. METHODS: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. RESULTS: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. CONCLUSIONS: Our data suggest that VMI at 60-70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.

13.
Eur Radiol ; 33(8): 5578-5586, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36890304

RESUMO

OBJECTIVES: Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT). METHODS: In this prospective study, 32 patients underwent PC-CT of the spine. Data was reconstructed in two ways: (1) standard bone kernel with 65-keV (PC-CTstd) and (2) 130-keV monoenergetic images (PC-CT130 keV). Prior EID-CT was available for 17 patients; for the remaining 15, an age-, sex-, and body mass index-matched EID-CT cohort was identified. Image quality (5-point Likert scales on overall, sharpness, artifacts, noise, diagnostic confidence) of PC-CTstd and EID-CT was assessed by four radiologists independently. If metallic implants were present (n = 10), PC-CTstd and PC-CT130 keV images were again assessed by 5-point Likert scales by the same radiologists. Hounsfield units (HU) were measured within metallic artifact and compared between PC-CTstd and PC-CT130 keV. Finally, the radiation dose (CTDIvol) was evaluated. RESULTS: Sharpness was rated significantly higher (p = 0.009) and noise significantly lower (p < 0.001) in PC-CTstd vs. EID-CT. In the subset of patients with metallic implants, reading scores for PC-CT130 keV revealed superior ratings vs. PC-CTstd for image quality, artifacts, noise, and diagnostic confidence (all p < 0.001) accompanied by a significant increase of HU values within the artifact (p < 0.001). Radiation dose was significantly lower for PC-CT vs. EID-CT (mean CTDIvol: 8.83 vs. 15.7 mGy; p < 0.001). CONCLUSIONS: PC-CT of the spine with high-kiloelectronvolt reconstructions provides sharper images, higher diagnostic confidence, and lower radiation dose in patients with metallic implants. KEY POINTS: • Compared to energy-integrating CT, photon-counting CT of the spine had significantly higher sharpness and lower image noise while radiation dose was reduced by 45%. • In patients with metallic implants, virtual monochromatic photon-counting images at 130 keV were superior to standard reconstruction at 65 keV in terms of image quality, artifacts, noise, and diagnostic confidence.


Assuntos
Doenças da Coluna Vertebral , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fótons , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/diagnóstico por imagem
14.
J Endovasc Ther ; 30(5): 739-745, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35582987

RESUMO

PURPOSE: Endoleaks are a common complication after endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR). The detection and correct classification of endoleaks is essential for the further treatment of affected patients. However, standard computed tomography angiography (CTA) provides no hemodynamic information on endoleaks, which can result in misclassification in complex cases. The aim of this study was to compare standard CTA (sCTA) with dynamic, dual-energy CTA (dCTA) for detection and classification of endoleaks following EVAR or TEVAR. MATERIALS AND METHODS: This retrospective evaluation compared 69 sCTA diagnostic examinations performed on 50 different patients with 89 dCTA diagnostic examinations performed on 69 different patients. RESULTS: In total, 15.9% of sCTA examinations and 49.4% of dCTA examinations led to the detection of endoleaks. With sCTA, 20.0% of patients were diagnosed with endoleaks, while with dCTA, 37.7% of patients were diagnosed with endoleaks. With sCTA, mainly Type 1 endoleaks were detected, whereas, with dCTA, the types of detected endoleaks were more evenly distributed. In comparison with the literature, the frequencies of endoleak types detected with dCTA better reflect the natural distribution than the frequencies detected with standard CTA. CONCLUSION: Based on the retrospective comparative evaluation, dCTA could pose a valuable supplementary diagnostic tool resulting in a more accurate and realistic detection and classification of suspected endoleaks.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Angiografia por Tomografia Computadorizada/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Correção Endovascular de Aneurisma , Meios de Contraste , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aortografia/métodos
15.
Herz ; 48(1): 55-63, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35006290

RESUMO

BACKGROUND: We investigated the feasibility of evaluating coronary arteries with a contrast-enhanced (CE) self-navigated sparse isotropic 3D whole heart T1-weighted magnetic resonance imaging (MRI) study sequence. METHODS: A total of 22 consecutive patients underwent coronary angiography and/or cardiac computed tomography (CT) including cardiac MRI. The image quality was evaluated on a 3-point Likert scale. Inter-reader variability for image quality was analyzed with Cohen's kappa for the main coronary segments (left circumflex [LCX], left anterior descending [LAD], right coronary artery [RCA]) and the left main trunk (LMT). RESULTS: Inter-reader agreement for image quality of the coronary tree ranged from substantial to perfect, with a Cohen's kappa of 0.722 (RCAmid) to 1 (LCXprox). The LMT had the best image quality. Image quality of the proximal vessel segments differed significantly from the mid- and distal segments (RCAprox vs. RCAdist, p < 0.05). The LCX segments showed no significant difference in image quality along the vessel length (LCXprox vs. LCXdist, p = n.s.). The mean acquisition time for the study sequence was 553 s (±46 s). CONCLUSION: Coronary imaging with a sparse 3D whole-heart sequence is feasible in a reasonable amount of time producing good-quality imaging. Image quality was poorer in distal coronary segments and along the entire course of the LCX.


Assuntos
Vasos Coronários , Coração , Humanos , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária , Imageamento por Ressonância Magnética , Imageamento Tridimensional
16.
Eur Radiol ; 33(4): 2461-2468, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36477938

RESUMO

OBJECTIVES: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography. METHODS: In this single-center retrospective study, 66 patients underwent photon-counting and conventional abdominal CT. Four radiologists assessed general image quality, image noise, and image artifacts. Signal-to-noise ratio and dose properties of both techniques within the clinical application were compared. An ex vivo phantom study revealed the radiobiological impact by means of DNA double-strand break foci in peripheral blood cells by enumerating γ-H2AX+53BP1 foci. RESULTS: General image quality in accordance with the Likert scale was found superior for photon-counting CT (4.74 ± 0.46 vs. 4.25 ± 0.54; p < 0.001). Signal-to-noise ratio (p < 0.001) and also dose exposure were higher for photon-counting CT (DLP: 419.2 ± 162.2 vs. 372.3 ± 236.6 mGy*cm; p = 0.0435). CT exposure resulted in significantly increased DNA damage in comparison to sham control (p < 0.001). Investigation of the average foci per cell and radiation-induced foci numbers revealed significantly elevated numbers (p = 0.004 and p < 0.0001, respectively) after photon-counting CT. CONCLUSION: Photon-counting CT in abdominal examinations showed superior results regarding general image quality and signal-to-noise ratio in clinical routine. However, this seems to be traded for a significantly higher dose exposure and corresponding double-strand break frequency. Optimization of standard protocols in further clinical applications is required to find a compromise regarding picture quality and dose exposure. KEY POINTS: • Photon-counting computed tomography promises to enhance the diagnostic potential of medical imaging in clinical routine. • Retrospective single-center study showed superior general image quality accompanied by higher dose exposure in initial abdominal PCCT protocols compared to state-of-the-art conventional CT. • A simultaneous ex vivo phantom study revealed correspondingly increased frequencies of DNA double-strand breaks after PCCT.


Assuntos
DNA , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Imagens de Fantasmas
17.
Int J Cardiovasc Imaging ; 38(11): 2459-2467, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36434338

RESUMO

Perivascular adipose tissue is known to be metabolically active. Volume and density of periaortic adipose tissue are associated with aortic calcification as well as aortic diameter indicating a possible influence of periaortic adipose tissue on the development of aortic calcification. Due to better spatial resolution and signal-to-noise ratio, new CT technologies such as photon-counting computed tomography may allow the detection of texture alterations of periaortic adipose tissue depending on the existence of local aortic calcification possibly outlining a biomarker for the development of arteriosclerosis. In this retrospective, single-center, IRB-approved study, periaortic adipose tissue was segmented semiautomatically and radiomics features were extracted using pyradiomics. Statistical analysis was performed in R statistics calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. For feature selection Random Forest classification was performed. A two-tailed unpaired t test was applied to the final feature set. Results were visualized as boxplots and heatmaps. A total of 30 patients (66.6% female, median age 57 years) were enrolled in this study. Patients were divided into two subgroups depending on the presence of local aortic calcification. By Random Forest feature selection a set of seven higher-order features could be defined to discriminate periaortic adipose tissue texture between these two groups. The t test showed a statistic significant discrimination for all features (p < 0.05). Texture changes of periaortic adipose tissue associated with the existence of local aortic calcification may lay the foundation for finding a biomarker for development of arteriosclerosis.


Assuntos
Tecido Adiposo , Arteriosclerose , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Valor Preditivo dos Testes , Tecido Adiposo/diagnóstico por imagem , Tomografia Computadorizada por Raios X
18.
Sci Rep ; 12(1): 20504, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-36443407

RESUMO

We hypothesized that myocardial septal scarring, assessed by cardiac magnetic resonance (CMR) using late gadolinium enhancement (LGE), at the site of cardiac contractility modulation (CCM) lead placement may predict treatment response. Eligible heart failure (HF) patients underwent LGE CMR imaging before CCM device implantation. The response to CCM therapy at follow-up was determined by a change in NYHA class and echocardiographic left ventricular ejection fraction (LVEF) assessment. Patients were classified as responders, if they showed an improvement in either NYHA class or improvement of LVEF by ≥ 5%. 58 patients were included. 67% of patients were classified as responders according to improved NYHA; 55% according to LVEF improvement. 74% of patients were responders if either NYHA class or LVEF improvement was observed. 90% of responders (according to NYHA class) showed septal LGE < 25% at septal position of the leads, while 44% of non-responders showed septal LGE > 25% (p < 0.01). In patients treated with CCM, an improvement of NYHA class was observed when leads were placed at myocardial segments with a CMR- LGE burden less than 25%.


Assuntos
Cicatriz , Insuficiência Cardíaca , Humanos , Cicatriz/diagnóstico por imagem , Volume Sistólico , Meios de Contraste , Função Ventricular Esquerda , Gadolínio , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia
19.
J Clin Med ; 11(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36294324

RESUMO

The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0−2965 (interquartile range (IQR) 0−135). The IQ was very good (one, IQR one−two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

20.
Sci Rep ; 12(1): 14228, 2022 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-35987779

RESUMO

Systemic mastocytosis (SM) is characterized by multifocal accumulation of neoplastic mast cells (MCs), predominately affecting the bone marrow (BM). Imaging with computed tomography (CT) is used for assessment of bone mineral density and structure. However, the value of functional imaging with dual-energy CT (DECT) and the assessment of virtual-non-calcium attenuation values (VNCa-AV) for visualization of BM disease burden in SM has not yet been assessed. DECT of the axial skeleton was performed in 18 patients with SM (indolent SM [ISM], n = 6; smoldering SM [SSM]/advanced SM [AdvSM], n = 12) and 18 control subjects. VNCa-AV were obtained in 5 representative vertebraes per patient and correlated with laboratory, morphologic and molecular parameters. VNCa-AV strongly correlated with quantitative BM MC infiltration (r = 0.7, R2 = 0.49, P = 0.001) and serum tryptase levels (r = 0.7, R2 = 0.54, P < 0.001). Mean VNCa-AV were significantly higher in SSM/AdvSM as compared to ISM (- 9HU vs. - 54HU, P < 0.005) and controls (- 38HU, P < 0.005). Nine of 10 (90%) patients with a VNCa-AV > - 30HU and 7/7 (100%) patients with a VNCa-AV > - 10HU had SSM or AdVSM. BM VNCa-AV provide information about the MC burden of SM patients and correlate with SM subtypes. DECT may therefore serve as a supplementary tool for SM diagnosis, subclassification and monitoring in a one-stop-shop session.